Part Number Hot Search : 
TP8482 25PT16A X1624 DSPIC3 BEFVAA4 2SJ518 2N22907 MCR10
Product Description
Full Text Search
 

To Download GS160A20-R7B Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  specification order no. dc voltage safety model no. rated current current range rated power (max.) ripple & noise (max.) note.2 output voltage range note.7 frequency range power factor (typ.) efficiency (typ.) ac current input environment inrush current (max.) leakage current(max.) safety standards safety & emc (note. 5) working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing protection gs160a15 gs160a15-r7b gs160a12 gs160a12-r7b gs160a20 GS160A20-R7B gs160a24 gs160a24-r7b gs160a48 gs160a48-r7b 15v 12v 20v 24v 48v 100mvp-p 80mvp-p 150mvp-p 180mvp-p 240mvp-p voltage tolerance note.3 line regulation note.4 load regulation 5.0% 3.0% 3.0% 1.0% 1.0% 1.0% 5.0% 3.0% 3.0% 85 ~ 264vac 120 ~ 370vdc 47 ~ 63hz pf>0.95 / 230vac pf>0.98 / 115vac at full load 90% 89% 92% 92.5% 94% 1.85a / 115vac 1a / 230vac 120a / 230vac 0.75ma / 240vac withstand voltage isolation resistance i/p-o/p: 3kvac i/p-o/p / 25 / 70% rh :100m ohms / 500vdc 290.3khrs min. mil-hdbk-217f(25 ) -30 ~ +70 (refer to "derating curve") 20% ~ 90% rh non-condensing -20 ~ +85 , 10 ~ 95% rh 0.03% / (0~50 ) 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes 175*72*35mm (l*w*h) 0.66kg; 20pcs/ 14.2kg/ 0.85cuft connector plug cable see page 2 ther type available by customer requested ; o see page 2 ther type available by customer requested ; o 1.all parameters are specified at 230vac input, rated load, 25 70% rh ambi ent. 2.ripple & noise are measured at 20mhz by using a 12" twisted pair terminated w ith a 0.1uf & 47uf capacitor. 3.tolerance: includes set up tolerance, line regulation, load regul ation. 4.line regulation is measured from low line to high line at rated load. 5.the power supply is considered a component which will be installed into a f inal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 6. length of set up time is measured at first cold start. turning on/off the powe r supply may lead to increase of the set up time. 7. derating may be needed under low input voltage. please check the deratin g curve for more details. 160w ac-dc single output desktop g s 1 6 0 s e r i e s features : compliance to en61000-4-2,3,4,5,6,8,11, light industry level, c riteria a overload over voltage 105 ~ 135% rated output power protection type : hiccup mode, recovers automatically after fault con dition is removed 105 ~ 135% rated output voltage 9.6a 11.5a 8a 6.67a 3.34a 0 ~ 9.6a 0 ~ 11.5a 0 ~ 8a 0 ~ 6.67a 0 ~ 3.34a 144w 138w 160w 160w 160w protection type : shut down o/p voltage, re-power on to recover ul60950-1, tuv en60950-1, bsmi cns14336, ccc gb4943, approved j60950-1(except for 48v) compliance to en55022(cispr22) ,en61204-3 class b, cns13438 class b , gb9254-1 class b, en61000-3-2,3, gb17625.1 universal ac input / full range 3 pole ac inlet iec320-c14 protections: short circuit / overload / over voltage / over temperature fully enclosed plastic case approvals: ul / cul / pse / tuv / bsmi / ccc / cb / fcc / ce class power (with earth pin) led indicator for power on no load power consumption<0.5w erp step2 compliant nrcan compliant meet eisa 2007 (energy independence and security act) 2 years warranty built-in active pfc function, pf>0.95 file name:gs160-spec 2012-03-06 setup, rise time note.6 hold up time (typ.) 2000ms, 20ms / 230vac 2500ms, 20ms / 115vac at full load 20ms / 230vac 20ms / 115vac at full load over temperature 90 10 (rth2) detect on inside ambient temperature protection type : shut down o/p voltage, re-power on to recover 5.0% 1.0% 5.0% 4.0% 1.0% 4.0% tuv rheinland product safety geprufresicherheit (except for 48v) emc immunity emc emission
derating curve static characteristics mechanical specification ambient temperature ( ) load (%) -30 20 10 30 40 20 40 80 60 100 60 50 70 input voltage (vac) 60hz 85 100 95 120 110 160 140 200 180 240 220 264 load (%) 85 100 80 70 60 50 40 (horizontal) plug assignment case no.997a unit:mm 50 230vac 100vac 30 3mm 175 35 72 ul2464 18awgx4c 1200 50mm 1 2 4 3 power led r7b standard plug: r7b pin no. 1,4 2,3 output +v -v 2 3 1 4 ac fg -v connected to ac fg 160w ac-dc single output desktop g s 1 6 0 s e r i e s file name:gs160-spec 2012-03-06


▲Up To Search▲   

 
Price & Availability of GS160A20-R7B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X